ICS-1100 Basic Integrated IC System

ICS-1100 Basic Integrated IC System

000

With dual-piston pumping and electrolytic suppression,the affordable ICS-1100 combines high sensitivity with set-and-forget convenience. Vacuum degas and column heater options further improve baseline stability and produce lower detection limits. The ICS-1100 comes with Chromeleon® SE data management software for automation and data handling.

Compact and easy to operate, the ICS-1100 delivers solid performance at an attractive price. Select Eluent Regeneration (RFIC-ER) system technology or 2 mm column chemistries to dramatically reduce eluent usage and costs. Automated sample preparation with the optional addition of a 6- or 10-port valve enables matrix elimination, filtration, and automated large loop/ small loop reinjection of samples.

Key Features:

  • Eluent regeneration functionality built in
  • Dual-piston pump
  • Electrolytic suppression
  • Digital conductivity detection
  • USB connectivity, plug-n-play
  • Optical leak detector
  • Electronic logbook and trending
  • Optional 6- or 10-port valve for automated sample preparation

Benefits:

  • Increase productivity with electrolytic suppression.
  • RFIC-ER system technology provides up to 28 days of chromatography results using only a single eluent preparation.
  • Automated sample preparation capabilities enable techniques, such as on-line filtration, concentration, and matrix elimination.
  • Enjoy contamination-free, trouble-free IC with durable PEEK flow paths which stand up to your toughest acidic and basic eluents.
  • The ICS-1100 is reliable, reproducible, and saves you time and money.
  • Eliminate preinjection sample processing with automated sample preparation techniques like filtration and matrix elimination.

 

ICS-1100 Basic Integrated IC System Specifications

Analytical Pump and Fluidics
Type Serial dual-reciprocating pistons, microprocessor-controlled constant stroke, variable speed
Construction Chemically inert, metal-free PEEK pump heads and flow paths compatible with aqueous eluents of pH 0–14 and reversed-phase solvents
Pump Operating Pressure 0–35 MPa (0–5000 psi)
Flow Rate Range 0.00–5.00 mL/min without changing pump heads
Flow Precision <0.1%, typically
Flow Accuracy <0.1%, typically
Pressure Ripple <1.0% at 13.8 MPa (2000 psi) and 1.0 mL/min
Eluent On-Off Valve Standard
Piston Seal Wash Dual-pump head, wash can be continuous when connected to rinse solution supply
Pressure Alarm Limits Upper limit 0–35 MPa or 0–5000 psi in one unit (MPa or psi) increments; lower limit can be set up to one unit lower than upper limit
Vacuum Degas Yes, optional, automatic control
Eluent Bottles Polypropylene, up to 4 L volume
Eluent Bottle Pressure Not required
Injection Valve 6-port, 2-position Rheodyne valve, electrically activated
Columns Supported 2, 3, 4, and 5 mm i.d.; maximum length 250 mm analytical column with 50 mm guard column
Column Heater (Optional)
Operating Temperature Range 30–60 °C (86–140 °F); minimum 5 °C above ambient. Settable range is equal to working range
Temperature Accuracy ±0.5 °C at sensor; at 40 °C
Auxiliary Valve (Optional) 2-position, 6- or 10-port high-pressure Rheodyne valve, fully inert PEEK construction, electrically activated
Eluent Generation (Optional with RFC-30)
Eluent Regeneration Support
(Yes, with optional RFIC-ER Startup Kit)
Eluents Carbonate and carbonate/bicarbonate combinations up to 20 mM; MSA up to 34 mM
Flow Rates 0.01–2.00 mL/min
Continuous Operation
(4 L Eluent)
Up to 28 days or 2000 samples, typically
Always On, Always Ready Capable Yes, standard feature
Remains fully calibrated for extended periods (<28 days) Yes, standard feature. Results are traceable to a single calibration.
System Wellness Consumables usage monitoring for predictive maintenance
Maximum Operating Pressure 21 MPa (3000 psi)
Operating Temperature Range 4–40 °C
Suppressors and Control
Chemical Suppression 2 mm and 4 mm anion and cation, membrane suppression bed types
Displacement Chemical Regeneration 2 mm and 4 mm anion and cation, membrane suppression bed types
Electrolytic Suppression- Self Regenerating 2 mm and 4 mm anion and cation. Both membrane and MonoDiskTM suppression bed types available
Electrolytic Suppression- Self Regenerating with External Water Mode 2 mm and 4 mm anion and cation. Both membrane and MonoDisk suppression bed types available
Current Control Range SRS (4 mm): 0–300 mA in 1 mA increments
SRS (2 mm): 0–100 mA in 1 mA increments
AES®: 0–150 mA in 1 mA increments
CMD: 0–500 mA in 1 mA increments
SRN: 0–500 mA in 1 mA increments
Salt Converter Available in 2 and 4 mm versions
AMMS-ICE Available in 2 and 4 mm versions
Carbonic Acid Removal for Anions ASRS 300 plus CRD 200 for hydroxide eluents
ASRS 300 plus CRD 300 for carbonate eluents
Non-Suppressed Chromatography Yes, supported
Suppressor Wear Parts None: peristaltic pump and inline filters are not required
Suppression Capacity Anion SRS 300 (4 mm): 200 µeq/min
Cation SRS 300 (4 mm): 110 µeq/min
Anion SRS 300 (2 mm): 50 µeq/min
Cation SRS 300 (2 mm): 37.5 µeq/min
Anion MMS 300 (4 mm): 150 µeq/min
Cation MMS 300 (4 mm): 150 µeq/min
Anion MMS 300 (2 mm): 37.5 µeq/min
Cation MMS 300 (2 mm): 37.5 µeq/min
Anion AES: 25 µeq/min
Cation AES:25 µeq/min
Suppressor Void Volumes SRS 300 (4 mm): <50 µL
SRS 300 (2 mm): <15 µL
MMS 300 (4 mm): <50 µL
MMS 300 (2 mm): <15 µL
AMMS-ICE 300 (4 mm): <50 µL
AMMS-ICE 300 (2 mm): <15 µL
AES (Anion or Cation): <35 µL
Conductivity Detector Electronics and Flow Cell
Type Microprocessor-controlled digital signal processor
Cell Drive 8 kHz square wave
Linearity 1% up to 1 mS/cm
Resolution 0.00238 nS/cm
Full-Scale Output Ranges Digital signal range: 0–15,000 µS/cm
Analog signal range: 0–15,000 µS/cm
Electronic Noise ±0.1 nS when background conductivity is 0–150 µS/cm
±2 nS when background conductivity is 151–3200 µS/cm
Filter Rise times from 0–10 s, user selectable
Temperature Compensation Fixed at 1.7% per 1 °C at cell temperature
Temperature Range Ambient +7 °C; 30 to 55 °C
Cell Electrodes Passivated 316 stainless steel. Compatible with MSA.
Cell Body Chemically inert polymeric material
Cell Volume <1 µL
Heat Exchanger Inert, convoluted-path for low axial dispersion
Maximum Cell Operating Pressure 10 MPa (1500 psi)
Autosampler
Automation Using Autosampler Thermo Scientific Dionex AS-AP, AS-DV, AS-HV, or third-party autosamplers
Sequential/Simultaneous Injection Yes, depending on autosampler capabilities
Automated Dilution Yes, available with AS-AP Autosampler
Dilution Factor, AS-Ap Autosampler 1:1 to 1:1000
Dilution Time, AS-AP Autosampler 15 seconds with sample overlap
Inline Sample Degassing Yes, optional with CRD 300/200
Inline Filtration Yes, AS-DV Autosampler or inline filter
High Automation Flexibility Conditionals using Chromeleon and post run features
System Software and Control
Software Chromeleon Chromatography Management Software, supports Microsoft Windows® 7, XP or Vista
Automated Procedure Wizards Yes, standard feature
System Wellness and Predictive Performance Yes, standard feature
Data Trending Plots Yes, numerical device parameters can be plotted
Virtual Column Simulator Yes, evaluation mode standard, isocratic and gradient optional
Application Templates Yes, standard feature
Multivendor Automation Support of 3rd Party Instruments Yes, fully controls over 300 different instruments from more than 30 manufacturers, including GC, HPLC, and MS
3-D Software for PDA, MS, and ED Yes, optional
Customizable System Control Panels Yes, standard feature
System Status Virtual Channels Yes, standard feature
Power Failure Protection Yes, standard feature
Sequential Injection Yes, standard feature for independent dual system analysis
System Trigger Commands and Conditionals Yes, standard feature
Daily Audit Trail Yes, standard feature
Sample Audit Trail Yes, standard feature
Multiple Network Control and Network Failure Protection Yes, optional
System Calibration Storage Yes, factory, present, and previous. Completely user selectable
Customized Reporting Yes, standard feature with unlimited report workbooks
Control Modes Full control through Chromeleon software; alternative control through TTL or relay closures; two relay outputs, two TTL outputs, four programmable inputs
Automated System Qualification Yes, automated IQ/OQ/PQ procedures produce detailed, comprehensive qualification reports using minimal operator time
USB Communication Protocol One USB input; one built-in two-port USB hub
Physical Specifications
Dimensions (h × w × d) 56.1 cm × 22.4 cm × 53.3 cm (22.1 × 8.8 × 21 in.)
Weight 24.5 kg (54 lb)
Power Requirements 100–240 V ac, 50–60 Hz, autoranging
Operating Temperature 4–40 °C (40–104 °F); cold-room compatible (4° C) as long as system power remains on
Operating Humidity Range 5–95% relative, non-condensing
Leak Detection Built-in, optical sensor